Working Principle:
Step 1: Calibrate a specific pressure by adjusting the compression nut of the spring
Step 2: Under normal operating pressure, the valve is closed
Step 3: When the pressure inside storage tank is over the set pressure, the valve opens automatically
Step 4: The pressure inside storage tank is released, the pressure value in pipe and equipment is restored to the set value range.
The glass cover is filled with water to seal the outlet hole. It is clearly visible through air bubbles in the glass cover when the valve discharges air out of storage tank.
Configuration:
Features:
| Working Pressure: | Max. 2.2 bar |
| Set Pressure Range: | 0.2 ~ 2.2 bar |
| Size: | DN15 ~ DN50 |
| Medium | Fluid or gas |
| Medium Temperature: | -10℃ ~ 120℃ |
| Material: | SS304 or SS316L |
| Sealing Material: | EPDM, FPM, Silicone |
| Connection End: | Weld, clamp, union |
| Other Option: | With or without gauge |